Enquiries answered within 5 hours

16S3P battery case — 48 cells, 60 V

A 16S3P pack is 48 cells: 16 groups in series, 3 in parallel in each group. This page lists the 21700 housings that actually take it, in the order of how much room they leave for the BMS and the wiring.

Short answer: 30 of our 110 housings take a 16S3P on 21700. 14 of those leave at least six cells of room — which is the practical minimum once a 16S BMS and the wiring are in.

The pack, in numbers

Cells48
Nominal voltage16 × 3.6 V = 60 V
Charge voltage16 × 4.2 V = 67.2 V
Capacity (typical)3 × 5.0 Ah = 15.0 Ah
Energy (typical)864 Wh

Capacity assumes 5.0 Ah per 21700 cell. Your cells will differ — the cell count and the voltage are exact, the capacity is a working figure.

Housings that take it

Model21700 ceilingRoom left
ALX032 · Rear Rack524
ALX035B · Silver Fish524
ALX040 · Silver Fish524
ALX069 · Rear Rack524
ALX077B · Downtube524
ALX082 · Hailong524
ALX097B · Hailong524
ALX099 · Downtube524
ALX100A · Downtube524
ALX106 · Integrated524
ALX108 · Integrated524
ALX114A · Rear Rack524
ALX114B · Rear Rack524
ALX122 · Integrated524

Showing the 14 with the most room. The other 16 are in the case selector.

Why room left matters more than the ceiling. A housing listed at 48 cells holds your pack exactly and nothing else — no BMS, no nickel, no cable exit. In practice a 16S pack needs roughly six cells of space beyond the cells themselves, because a 16S BMS is longer than the 10S board these moulds were designed around. That is the single most common reason a build that “fits” does not close. There is a longer explanation in why your 13S5P pack will not fit.

Work out your own configuration

The pack calculator does this for any series and parallel count, and the case selector takes a plain cell count if you already know it.

What 864 Wh actually gets you

The figure above is energy, not distance. A 16S3P pack on 21700 works out to about 864 Wh, which is roughly 72–108 km on low assist and 27–39 km at full assist for a 75 kg rider on mixed terrain. How far a pack will take you explains what moves that figure, and how the same configuration on the other cell format compares.

Other configurations

The parallel count is what changes the housing, not the series count.

Common questions

How many cells is a 16S3P pack?
48 cells — 16 groups wired in series, 3 cells in parallel in each group.
What voltage is 16S?
60 V nominal (16 x 3.6 V), charging to 67.2 V.
Which battery case takes a 16S3P pack on 21700?
30 of our housings take it. 14 leave at least six cells of room for the BMS and wiring.
Can I use a 16S3P pack in a case listed at fewer cells?
No. The listing is the ceiling. If a housing says it takes 45 cells it will not take 48.

Send us the pack and we will confirm the fit

Cell format, series and parallel count is usually enough to answer the same day. If the answer is that none of our moulds fit, we will say so.