Enquiries answered within 5 hours
Get a Free Quote

10S4P battery case — 40 cells, 36 V

A 10S4P pack is 40 cells: 10 groups in series, 4 in parallel in each group. This page lists the 18650 housings that actually take it, in the order of how much room they leave for the BMS and the wiring.

Short answer: 133 of our 180 housings take a 10S4P on 18650. 111 of those leave at least six cells of room — which is the practical minimum once a 10S BMS and the wiring are in.

The pack, in numbers

Cells40
Nominal voltage10 × 3.6 V = 36 V
Charge voltage10 × 4.2 V = 42.0 V
Capacity (typical)4 × 3.5 Ah = 14.0 Ah
Energy (typical)504 Wh

Capacity assumes 3.5 Ah per 18650 cell. Your cells will differ — the cell count and the voltage are exact, the capacity is a working figure.

Housings that take it

Model18650 ceilingRoom left
ALX003 · Integrated400
ALX011 · Integrated400
ALX014 · Integrated400
ALX216 · Rear Rack400
ALX217 · Rear Rack400
ALX219 · Rear Rack400
ALX220 · Rear Rack400
ALX221 · Rear Rack400
ALX222 · Rear Rack400
ALX232 · Rear Rack400
ALX234 · Rear Rack400
ALX235 · Rear Rack400
ALX236 · Rear Rack400
ALX248 · Downtube400

Showing the 14 with the most room. The other 119 are in the case selector.

Why room left matters more than the ceiling. A housing listed at 40 cells holds your pack exactly and nothing else — no BMS, no nickel, no cable exit. In practice a 10S pack needs roughly six cells of space beyond the cells themselves, because a 10S BMS is longer than the 10S board these moulds were designed around. That is the single most common reason a build that “fits” does not close. There is a longer explanation in why your 13S5P pack will not fit.

Work out your own configuration

The pack calculator does this for any series and parallel count, and the case selector takes a plain cell count if you already know it.

What 504 Wh actually gets you

The figure above is energy, not distance. A 10S4P pack on 18650 works out to about 504 Wh, which is roughly 42–63 km on low assist and 16–23 km at full assist for a 75 kg rider on mixed terrain. How far a pack will take you explains what moves that figure, and how the same configuration on the other cell format compares.

Other configurations

The parallel count is what changes the housing, not the series count.

Common questions

How many cells is a 10S4P pack?
40 cells — 10 groups wired in series, 4 cells in parallel in each group.
What voltage is 10S?
36 V nominal (10 x 3.6 V), charging to 42.0 V.
Which battery case takes a 10S4P pack on 18650?
133 of our housings take it. 111 leave at least six cells of room for the BMS and wiring.
Can I use a 10S4P pack in a case listed at fewer cells?
No. The listing is the ceiling. If a housing says it takes 37 cells it will not take 40.

Send us the pack and we will confirm the fit

Cell format, series and parallel count is usually enough to answer the same day. If the answer is that none of our moulds fit, we will say so.

WhatsApp Get a Quote